100% EMISSIONS FREE
Clean off-grid power
The H2X generators are the zero emissions replacement for traditional diesel generators. This clean power solution is ideal for multiple off-grid power applications such as construction sites, outdoor events, and underground mining.
Ideal for telecommunication tower’s back-up power
Note: The Fuel Cell Generator is not yet in production. Individual specifications may therefore be subject to change depending on region and before the start of production.
PERFORMANCE
Fuel Cell | 2KW |
Dimension(H*L*W)mm | 749 x 887 x 555 |
Weight(KG) | 126 |
Power output(KW) | 2 |
Electrical Efficiency | ≥54% |
Rated voltage | 220~230 VAC |
Environment Humidity | 10%~95% |
Frequency | 50Hz |
HYDROGEN
Hydrogen consumption(kg/hr) | 0.75 kg/hr |
Hydrogen purity | >99.99% |
Supply pressure | 50kPa to 100kPa |
OPERATION
Operating temperature | -10˚C to 50˚C |
Operating humidity (RH) | 3% to 100% |
Working altitude | Up to 2,000m above sea level |
Noise | < 45 dB |
Outputs | Single/triple phase, AC/DC as required |
Starting time | 10-20 seconds |
Grid Adaptation | 400V AC in 3p+n / 50Hz |
Maintenance | Every 2,000 hours or annual preventative maintenance,which ever is sooner. |
Communication Interface | CAN Bus or Ethernet |
Warranty | 5000 Hours or 5 years,which ever is sooner |
Ideal for small house appliances
Note: The Fuel Cell Generator is not yet in production. Individual specifications may therefore be subject to change depending on region and before the start of production.
PERFORMANCE
Fuel Cell | 5KW |
Dimension(H*L*W)mm | 749 x 887 x 555 |
Weight(KG) | 180 |
Power output(KW) | 5 |
Electrical Efficiency | ≥54% |
Rated voltage | 220~230 VAC |
Environment Humidity | 10%~95% |
Frequency | 50Hz |
HYDROGEN
Hydrogen consumption(kg/hr) | 0.102 kg/hr |
Hydrogen purity | >99.99% |
Supply pressure | 50kPa to 100kPa |
OPERATION
Operating temperature | -10˚C to 50˚C |
Operating humidity (RH) | 3% to 100% |
Working altitude | Up to 2,000m above sea level |
Noise | < 45 dB |
Outputs | Single/triple phase, AC/DC as required |
Starting time | 10-20 seconds |
Grid Adaptation | 400V AC in 3p+n / 50Hz |
Maintenance | Every 2,000 hours or annual preventative maintenance,which ever is sooner. |
Communication Interface | CAN Bus or Ethernet |
Warranty | 5000 Hours or 5 years,which ever is sooner |
Ideal for small construction equipment
Note: The Fuel Cell Generator is not yet in production. Individual specifications may therefore be subject to change depending on region and before the start of production.
PERFORMANCE
Fuel Cell | 10KW |
Dimension(H*L*W)mm | 1050 x 1000 x 610 |
Weight(KG) | 250 |
Power output(KW) | 10 |
Electrical Efficiency | ≥54% |
Rated voltage | 220~230 V/AC or 380 V/AC |
Environment Humidity | 10%~95% |
Frequency | 50Hz |
HYDROGEN
Hydrogen consumption(kg/hr) | 0.255 kg/hr |
Hydrogen purity | >99.99% |
Supply pressure | 50kPa to 100kPa |
OPERATION
Operating temperature | -10˚C to 50˚C |
Operating humidity (RH) | 3% to 100% |
Working altitude | Up to 2,000m above sea level |
Noise | < 45 dB |
Outputs | Single/triple phase, AC/DC as required |
Starting time | 10-20 seconds |
Grid Adaptation | 400V AC in 3p+n / 50Hz |
Maintenance | Every 2,000 hours or annual preventative maintenance,which ever is sooner. |
Communication Interface | CAN Bus or Ethernet |
Warranty | 5000 Hours or 5 years,which ever is sooner |
Ideal for medium construction equipment and outdoor entertainment equipment
Note: The Fuel Cell Generator is not yet in production. Individual specifications may therefore be subject to change depending on region and before the start of production.
PERFORMANCE
Fuel Cell | 20KW |
Dimension(H*L*W)mm | 1200 x 1200 x 1200 |
Weight(KG) | 330 |
Power output(KW) | 20 |
Electrical Efficiency | ≥54% |
Rated voltage | 220~230 V/AC or 380 V/AC |
Environment Humidity | 10%~95% |
Frequency | 50Hz |
HYDROGEN
Hydrogen consumption(kg/hr) | 1.02 kg/hr |
Hydrogen purity | >99.99% |
Supply pressure | 50kPa to 100kPa |
OPERATION
Operating temperature | -10˚C to 50˚C |
Operating humidity (RH) | 3% to 100% |
Working altitude | Up to 2,000m above sea level |
Noise | < 45 dB |
Outputs | Single/triple phase, AC/DC as required |
Starting time | 10-20 seconds |
Grid Adaptation | 400V AC in 3p+n / 50Hz |
Maintenance | Every 2,000 hours or annual preventative maintenance,which ever is sooner. |
Communication Interface | CAN Bus or Ethernet |
Warranty | 5000 Hours or 5 years,which ever is sooner |
Coming Soon
Note: The Fuel Cell Generator is not yet in production. Individual specifications may therefore be subject to change depending on region and before the start of production.
PERFORMANCE
Fuel Cell | Coming Soon |
Dimension(H*L*W)mm | |
Weight(KG) | |
Power output(KW) | |
Electrical Efficiency | |
Rated voltage | |
Environment Humidity | |
Frequency |
HYDROGEN
Hydrogen consumption(kg/hr) | Coming Soon |
Hydrogen purity | |
Supply pressure |
OPERATION
Operating temperature | Coming Soon |
Operating humidity (RH) | |
Working altitude | |
Noise | |
Outputs | |
Starting time | |
Grid Adaptation | |
Maintenance | |
Communication Interface | |
Warranty |
Coming Soon
Note: The Fuel Cell Generator is not yet in production. Individual specifications may therefore be subject to change depending on region and before the start of production.
PERFORMANCE
Fuel Cell | Coming Soon |
Dimension(H*L*W)mm | |
Weight(KG) | |
Power output(KW) | |
Electrical Efficiency | |
Rated voltage | |
Environment Humidity | |
Frequency |
HYDROGEN
Hydrogen consumption(kg/hr) | Coming Soon |
Hydrogen purity | |
Supply pressure |
OPERATION
Operating temperature | Coming Soon |
Operating humidity (RH) | |
Working altitude | |
Noise | |
Outputs | |
Starting time | |
Grid Adaptation | |
Maintenance | |
Communication Interface | |
Warranty |
HYDROGEN
Generate power by chemistry, not burning
The H2X Global generators produce electricity in the fuel cell by mixing oxygen molecules from the air and hydrogen molecules from an external hydrogen canister.
CLEAN POWER FOR ALL
Customer Applications
Remote Locations
Telecommunications
Events
Mining and Constructions sites
Airports and Ports
Disaster Relief
TOTAL SOLUTION
Giving power to your energy needs
H2X generators are built to meet your professional power requirements. For further information please contact us.